Electro rent is a global provider of test and measurement equipment solutions including new and certified used equipment available for rent, lease or purchase. Retained mode, modifying primitives, points, colours and texture coord pdata. This control room software package acw can be used by all procal analysers. The extremely short measuring cycles make of fluxus chart recorder or plc. This unit does not include the transducer modules and has been priced accordingly. Fluxus adm 7x07 technical specification dimensions and mounting dimensions in mm fluxus adm 7407 fluxus adm 7907 10 70. Installed on a pc running microsoft windows nt, 98 or 95, acw is a standalone program that provides all the control and display. Its ergonomic design offers simple handling and maximum ease of use. The application of pulsation ratio preprocessing method in. There is also a fluxus adm 6725 in the departments equipment storage. Flexim products adm series fluxus adm 6725 the portable flowmeter portable flow measurement in clampon technique, ideal for service quick start guide fluxus adm 5107 quick start guide the water fluxus economy ultrasonic flowmeterfor the water and wastewater industry fluxus adm 7404 quick start guide the multitalented ultrasonic flowmeterfor. Flexims range of fluxus flow meters supports the hart communication protocol. Products, permanent flowmeters for liquids, fluxus f721 standard.
The numerous improvements implemented, are derived from years of application practice. A variety of process parameters can be measured and handled. Flexim fluxus f601 in stock, we buy sell repair, price quote. Flexim 02504399 battery for flexim fluxus adm 6725 x6725. View online or download katronic technologies fluxus adm 6725 operating instruction. The fluxus f601 is more than just an upgrade to its succesor, the fluxus adm 6725, an instrument display. Flexim provides atex authorized transducers and sensors for zone 1. Optimization of parabolic trough power plant operations in. Flexim fluxus ultrasonic liquid flow meters adm series brochure 1. Fluxus can measure volume flow, flow velocity or mass flow of liquids within a temperature range from 30 c up to c. This flexim fluxus f601 ultrasonic flow meter is used and in excellent condition.
The measurement is therefore noninvasive, and no process interruption is necessary for the installation. Flexim fluxus ultrasonic liquid flow meters adm series. Technical specification fluxus adm 7x07 fluxus adm 7407. Specification of the ultrasonic flowmeter fluxus adm 6725. Katronic technologies fluxus adm 6725 pdf user manuals. Flexim water and wastewater flow measurement at subsurface buried pipes duration. Fluxus is a rapid prototyping, playing and learning environment for 3d graphics, sound and games. Flexim fluxus f601 kit 3 available to buy or hire from. Fluxus adm 6725 mobiler ultraschall durchfluss ehlers. Portable clampon flowmeter, ideal for service work. Germany flexim adm 5107 economy ultrasonic flow meters. The main measured parameters are the flow rate, temperature, pressure, and differential pressure. The fluxus adm 6725 is the first portable ultrasonic flowmeter using the dual p technology, in which the special digital signal processor dsp is supported by a second microprocessor during the complex measuring process. Transducers are available for a wide range of inner pipe diameters 14 to 63 inches, dynamic.
These vector graphic formats can be imported into several layout and draw. Moreover, the flow meters for permanent installation can be integrated by the fdt dtm device manager into any fdt frame application. The department decided to purchase another of flexims portable fluxus f601 energy, not least because of the reliability of the old acoustic flowmeter. Flexim f601 standard lt available to buy or hire from. The flow rate of primacysecondary circuit of the test channel is measured by ultrasonic flowmeter fluxus adm, 6725 with the precision of 1. Universal sensor adapter 2 ultrasonic couplant gel tubes fluxus software assorted cables view photo of universal sensor. In difficult times likes this katronic want to assure you that the offices are still open for business. It is driven by guile scripting, and includes a physics engine, artificial life tools, and sound analysis. The clampon flow transducers are mounted onto the pipe instead of inserted into it. The fluxus f601 is more than just an upgrade to its successor, the fluxus adm 6725, an instrument which has proven itself in thousands of applications. Flexim fluxus f601 kit 3 available to buy or hire from bsria. The fluid temperature of inletoutlet is measured by. Evaluation of commercially available virtual flow meters vfms. Fluxus fluxus in times of rising energy prices and environmental regulations, optimization of energy flow is a most crucial issue.
Overview overview fluxus adm 6725 is a flowmeter that uses ultrasound to measure the flow in closed pipes or conduits. The fluxus adm 6725 flexim flow meter of ineosspecial measurement engineering can be used in zone 1 explosive conditions. Fluxus or similar software is one of many analytic techniques to be employed in genetic genealogy. Here as well as in all instruments of the fluxus adm series, the digital signal processor dsp and the high number of measuring cycles guarantee stable and reliable measuring results even under difficult conditions. Mnoha vylepseni byla provedena na zaklade dlouholetych praktickych zkusenosti v terenu. Katronic specialises in clampon ultrasonic flow meters and noninvasive process measurement instrumentation with modern electronics and sensor technology. Even sturdier than its predecessor, f601 is ideally suited to the rough conditions in industrial environments.
Network network publisher addon network publisher functions network publisher is an extended version of the free network software s draw subprogram, reading network results. Operation principle is a time difference law, are measured with ultrasonic signal spread speed and relation of the fluid velocity of flow in the fluid. Fluxus manual en, pdf fluxus manual fr, pdf fluxus on flossmanuals fluxus wiki function reference. Flexim leading uitrasonic flow measurement 2,506 views. Their uses may be obvious to the expert cladisticist, but not to many dna project administrators. Flexim fluxus f601 portable ultrasonic multifunctional. User manual umfluxus f8v40en ultrasonic flowmeter for. For this purpose the loops were equipped with a flexim fluxus adm 6725 clamp on ultrasonic flow meters with wave injectors for high temperature applications at the loop center cross over piping and a clampon temperature measuring system based on pt100s at the loop inlet and outlet nouri et al. Fluxus f601 is more than just an upgrade to the fluxus adm 6725, an instrument which has proven itself in thousands of applications. Fluxus adm 6725 is a portable transittime clamp on ultrasonic flow meter newly released by flexim instruments with additional functions such as energy flow computations as well as other new measurement features. Specifications fluxus adm 6725 fluxus adm 6725 is a portable ultrasonic flowmeter.
Fluxus adm 6725 pdf manuals and user guides for katronic technologies fluxus adm we have 1 katronic technologies fluxus adm manual available for free pdf. Liquid ultrasonic flowmeter for permanent installation. The fluxus f601 is more than just an upgrade to its succesor, the fluxus adm 6725, an instrument which has proven itself in thousands of applications. The numerous improvements implemented were derived from years of application practice. Flexim flexible industriemesstechnik gmbh non intrusive. Extends the racket language with graphical commands and can be used within its own livecoding environment or from within the drracket ide.
Fluxus flow meters, the g704 features an automatic loading of calibration data and transducer detection to reduce setup times and to provide precise, longterm stable results. Flexim f601 standard lt available to buy or hire from bsria. Every where, controlling and balancing the flowof energy is of utmost importance for costconscious users. Fluxus adm 6725 automatic transducer detection portable flow measurement with 2 flow channels automatic transducer detection easy installation without cutting into the pipe and without process interruption. With its clampon transducers and its rechargeable bat. With one or two flow channels and versatile electrical inputs and outputs, it can be optimally configured for your measuring application.
Fluxus adm 6725 technical data measuring measuring principle. A system comprises a transmitter and one or two pairs of special ultrasonic transducers which are simply clamped onto the outside of the pipe and never come in direct contact with the liquid. Fluxus adm 6725 ausgabeoptionen festlegen par sf parameter onen fur kanai a mebkanal auswohlen me. Flexim ultrasonic clampon hazardous area flow meters.